3-1. Washing Cycle
1) Classification of Washing
$ Pre-washing and soaking are carried out before main washing cycle.
% Decided value refers to water level and time decided by load sensing in standard, boiling and thrifty
boiling courses. In other sources, it means the pre-set time according to the designated water level.
& Soaking is the cycle consisted with water supply and washing only. Main washing begins
immediately after this cycle without drainage.
' In pre-washing and soaking cycles, only cold water is used and heating is not administered.
2) Heater Operation
$ Washing heater does not re-operate once turned off after reaching the set temperature.
% Even when target water temperature is not reached, washing cycle is finished when washing time
expires.
3) Re-supply of water
$ Re-supply is carried out in case water level detected per 2 minute after water supply completion is
lower than the set water level.
% Motor is stopped during re-supply.
& During washing, re-supply is carried out up to 10 times. After the 10th time, re-supply is not
administered even if water level drops.
' Re-supply is not carried out if more than half of washing time has passed and heater is turned off.